GRID SWITCH(R)

Metal Particle Detector

DETECTS DANGEROUS WEAR IN LUBRICATED MACHINERY

INSTALLATION

Installation Notes
Grid Switch MUST be mounted with the grid element in the horizontal position.
All piping to be minimum 1/4" I.D. or 3/8" O.D. tubing



SPECIFICATIONS

Body
Aluminum cast and machined with Viton(R) seals.

Grid Element
Grids etched on both sides of copper-clad, laminated fiberglass(3/32").
Copper grids are plated with nickel and 24K gold. Perforations are 1/32" drilled holes and the grid spacing is 1/16" .

Electrical rating
The detector should be connected to a control circuit requiring a maximum power of 3.5 va. A circuit voltage of 24 volts maximum (AC or DC) is recommended for operator safety.

Maximum recommended working pressure
200 psi

Minimum/maximum operating temperature
-15 degrees F to 400 degrees F (-25 C to 205 C)
Shipping weight
3 lbs (1.4 Kg)



Home | Back | Request Info

INDUSTRIAL DIESEL
PRODUCTS INC.

Worldwide Procurement Solutions
7075 Tranmere Dr.
Unit 7
Mississauga, Ontario, Canada
L5S 1M2
Tel: (905) 362-0423 Fax (905) 362-5015
E-Mail:sales@dieselproducts.com